<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-06 05-41-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 3/5, 41 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 66 kHz 2960 0,1351
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,0 dBr 5,40 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 66 kHz MIN: 12 kHz % above 76 kHz: 0,1351 Acquired: 2026/05/06 5.40.22 Total samples: 2960 Equivalent time: 0:02:28 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: 6,2 dBr MIN: 4,0 dBr AVE: 5,40 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2026/05/06 5.40.22) 05.26 05.28 05.30 05.32 05.34 05.36 05.38 05.40 0 2 4 6 Pm [dBr]